  • 外形图.jpg

SBL semi-automatic cleaning oil filter

SBL semi-automatic cleaning filter is mainly used for filtering fuel, lubricating oil and diesel oil to filter out dirt insoluble in oil to ensure the cleanliness of the oil. Other occasions can be used according to the conditions.

Classification:

Keywords: Filter | Valve Remote Control Device | Marine Module | Hydraulic

  • Product Description

    Overview Overview


    SBL semi-automatic cleaning filter is mainly used for filtering fuel, lubricating oil and diesel oil to filter out dirt insoluble in oil to ensure the cleanliness of the oil. Other occasions can be used according to the conditions.
    The filter is a candle-type filter element, which has the characteristics of high filtration efficiency, low original pressure and convenient cleaning. Working pressure 0.6~1.0Mpa, working temperature ≤ 150 ℃.
    SBL type semi-automatic cleaning filter is mainly used for fuel oil,lube oil and diesel oil which can filter insoluble oil contamination to keep the oil clean.On other occasions it can be used according to conditions
    Filter element type is candle type,the filtration is high and original pressure is small.It is easy and convenient to clean.The working pressure is 0.6-1.0Mpa,working temperature≤150℃

    1. Characteristic Features:
    When the pressure drop of the filter reaches the specified value, the filter can be cleaned without stopping as long as the handle is manually turned back and forth several times. Filter mesh material is 1Cr18Ni9Ti
    When the filter pressure drop is up to the required value we can just rotate the handle manually for several times.Material of filter screen is 1Cr18Ni9Ti.

    2. Working characteristics and cleaning methods Working characteristics and cleaning methods
    When the filter works normally, it can work in two chambers at the same time or in a single chamber. When the handle is in the vertical position, the two chambers work simultaneously; when the handle is in the right (left) position and the horizontal position, the left (right) chamber works normally.
    Cleaning method
    Left cavity cleaning: quickly rotate the switch handle from the vertical position to the left by 60 degrees, flush instantaneously for 1-2 seconds, rotate the handle back and forth several times, and then turn the switch handle back to the vertical position to complete the cleaning of the left cavity.
    Right chamber cleaning: quickly turn the switch handle to the right from the vertical position by 60 degrees, flush it instantaneously for 1-2 seconds, turn the handle back and forth several times, and then turn the switch handle back to the vertical position to complete the cleaning of the right chamber.
    When the filter element needs to be removed for cleaning, if the handle is turned 90 degrees to the left from the vertical position, the left cavity will stop working and the right cavity will work normally. At this time, the left cavity can be removed for cleaning; if the handle is turned 90 degrees to the right from the vertical position, the right cavity will stop working and the left cavity will work normally. At this time, the right cavity can be removed for cleaning.

    3. Precautions for use
    When the filter is used to filter heavy oil, light diesel oil should be introduced to flush the heavy oil in the filter before the shutdown after each use, so as to prevent the heavy oil from condensing on the surface of the filter element assembly after the temperature drops, which will affect the next use.
    Filter can work simultaneously with two chamber and also can work with single chamber.When the handle is at vertical position the two chambers work together.When the handle is at the right(left)position or horizontal position,the left(right)chamber works.
    Cleaning methods
    Left chamber cleaning:The handle at the vertical position can be quickly turned left of 60°and the left chamber can be transiently flushed for 1-2 seconds.Turn the handle back and forth for several times and then back to vertical position.The left chamber cleaning is complete.
    Right chamber cleaning:The handle at the vertical position can be quickly turned left of 60°and the right chamber can be transiently flushed for 1-2 seconds.Turn the handle back and forth for several times and then back to vertical position.The right chamber cleaning is complete.
    When the filter element needs cleaning,please kindly turn handle from the vertical position to the left 90°.The left chamber stops working and right chamber works normally.At that time the left chamber can be dismantled for cleaning.Rotate the handle from the vertical position to the right 90°.The right chamber stops working,the left chamber works normally and right chamber can be dismantled can be dismantled for cleaning.
    Precautions for use
    When the filter is used for heavy fuel oil,we should pour in the light diesel oil to keep the chamber clean every time before hauling.If not,heavy fuel oil will condense on the surface of filter element at lower temperature and affect next usage.

     

    2. Model Description Model description

     

    1

     

    3. Basic Dimension Table

     

    1

    Model
    Type

    Flow Rate (Reference)
    m³/h
    Flow rate(reference)

    Diameter and connection dimension (mm)
    Diameter and connection dimension

    Overall dimension (mm)
    Outline dimension

    DN

    A

    B

    R

    r

    4-M1

    H1

    H2

    H3

    F

    G

    K

    SBL20

    1-2

    20

    62

    55

    28

    11

    M10

    360

    77

    45

    110

    98

    222

    206

    SBL25

    2-4

    25

    SBL32A

    4-7

    32

    75

    70

    35

    15

    M12

    385

    92

    54

    130

    125

    265

    226

    SBL40

    7-10

    40

    480

    94

    52

    Installation dimension (mm)
    Mounting dimension

    Weight (kg)
    Weight

    W

    V

    Y

    Z

    4-M2

    100

    70

    75

    35

    M10

    25

    30

    122

    80

    90

    40

    M12

    47

    50

    Note: The filter can be installed upside down and connected to the outside through 4 bolts in direction A.
    Ntoe:Filter can be installed inversely and connect four bolts and outside world via A.

     
    Note:
    1. It is connected with the outside world with 4 bolts without base B. The inlet and outlet are at the bottom of the body and go out after moving forward.
    2. The two holes on the base near the handle are both inlets, and the remaining two holes are outlets. During installation, the inlet and outlet on the left and right sides can be arbitrarily selected, and the remaining inlet and outlet can be sealed with blind hole flanges.
    1、It can work without base B and connect four bolts and outside world via A.Inlet and outlet is on the bottom of the body,front-in and back-out.
    2、Two holes on the base near the handles are all inlets,other two holes are outlets.Inlets and outlets on both left and right side are optional when mounting.The left inlets and outlets can be blocked by blind flange.

     

    1

     

    DN50-80 technical parameters


    Model
    Type

    Flow Rate (Reference)
    m³/h
    Flow rate(reference)

    Diameter and connection dimension (mm)
    Diameter and connection dimension

    Overall dimension (mm)
    Outline dimension

    DN

    D

    K

    4-M1

    H1

    H2

    H3

    H4

    F

    G

    H

    SBL50

    10-25

    50

    120

    110

    M12

    540

    253

    184

    86

    165

    155

    330

    350

    SBL65

    25-30

    65

    750

    SBL80

    25-40

    80

    146

    182

    M14

    740

    320

    224

    102

    200

    190

    424

    400

    Installation dimension (mm)
    Mounting dimension

    Weight (kg)
    Weight

    P

    J

    4-M2

    W

    V

    Y

    Z

    X

    4-M3

    258

    136

    -14

    150

    115

    110

    78

    13

    M12

    67

    16

    71

    334

    244

    ∅16

    200

    145

    160

    100

    26

    M16

    135

     

    1


    DN100-125 technical parameters


    Model
    Type

    Flow Rate (Reference)
    m³/h
    Flow rate(reference)

    Diameter, connection and dimension (mm)
    Diameter and connection dimension、outline dimension

    Weight (kg)
    Weight

    DN

    D

    D1

    D2

    n-d

    H

    SBL100

    60-100

    100

    250

    180

    158

    8-M16

    965

    248

    SBL125

    125

    210

    184

    8-M16

    1066

    254

     

    1

     


    Model
    Type

    Flow Rate (Reference)
    m³/h
    Flow rate(reference)

    Diameter, connection and dimension (mm)
    Diameter and connection dimension、outline dimension

    Weight (kg)
    Weight

    DN

    D

    D1

    D2

    n-d

    H

    SBL150

    100-170

    150

    340

    240

    212

    8-M20

    1160

    579

    SBL200

    200

    295

    268

    8-M20

    1260

    610

Related Products

Product Message