  • 图片SPL、DPL船用柴油机网片式油滤器.jpg
  • 图片SPL15-40.jpg
  • 图片SPL65,80.jpg

DPL, SPL marine diesel engine single, double cylinder mesh oil filter

Marine diesel engine mesh oil filter is manufactured according to CB/T3025 standard. The product points DPL, SPL single, double tube two series. The product is suitable for the filtration of lubricating oil and fuel system of various types of marine diesel engines and land diesel engines, and can also be used in petroleum, chemical, electric power and other industries.

Classification:

Keywords: Filter | Valve Remote Control Device | Marine Module | Hydraulic

  • Product Description

    Overview

     

    Marine diesel engine mesh oil filter is manufactured according to CB/T3025 standard. The product points DPL, SPL single, double tube two series. The product is suitable for the filtration of lubricating oil and fuel system of various types of marine diesel engines and land diesel engines, and can also be used in petroleum, chemical, electric power and other industries.

    The product is characterized by large oil capacity, reduced original pressure, long cleaning cycle, and easy maintenance. In particular, SPL series products can realize non-stop cleaning during the operation of the host to ensure the continuous operation of the system. In addition, the oil filter can also be equipped with a differential pressure display, alarm function of the differential pressure transmitter, so that when the oil filter inlet and outlet drop reaches the specified value, timely cleaning. (Note: The differential pressure transmitter is an optional accessory and can be indicated when ordering.)

     

    Model Description

     

    1

     

    Selection parameter table

     


    Working temperature cleaning pressure drop Work Temp.≤ 95 ℃;Clean drop pressure ≤ 0.15Mpa
    Working pressure Work pressure ≤ 0.8Mpa;

    Model Type

    Path DN
    (mm)

    Rated flow
    Flow rate
    (m³/h)

    Double Barrel Series
    SPL series

    Single cylinder series
    DPL series

    SPL15

     

    15

    2

    SPL25

    DPL25

    25

    5

    SPL32

     

    32

    8

    SPL40

    DPL40

    40

    12

    SPL50

     

    50

    20

    SPL65

    DPL65

    65

    30

    SPL80

    DPL80

    80

    50

    SPL100

    DPL100

    100

    80

    SPL125

     

    125

    120

    SPL150

    DPL150

    150

    180

    SPL200

    DPL200

    200

    320

    Note: For the clean oil with the test medium viscosity of 24cst, the original pressure drop of the filter shall not be greater than 0.08Mpa when testing the rated flow rate.
    Note:Clean oil whose test medium viscosity is 24 cst.The primary drop pressure is less than 0.08Mpa when the filter is on rated flux state.

    Note: For the clean oil with the test medium viscosity of 24cst, the original pressure drop of the filter shall not be greater than 0.08Mpa when testing the rated flow rate.
    Note: Clean oil whose test medium viscosity is 24 cst.The primary drop pressure is less than 0.08Mpa when the flter is on rated flux state.
    Indicate when ordering:
    1. Installation form: D-top-mounted C- side-mounted X-down-mounted
    2, mesh number or mesh size
    3. Filter material: usually stainless steel mesh, or copper mesh
    Please note:
    1、Mount type: D-hang mounting type C-side mounting type X-underside mounting type
    2、Mesh No.or mesh hole dimension(see attachment)
    3、Material of fIlter pan: Nomal stainless steel or copper

     

    Double-barrel mesh oil filter for SPL marine diesel engine
     

    11

     

    Main dimension table of SPL dual-cylinder screen-pan oil filter

    Path
    DN
    (mm)

    Installation form
    Mounting
    Type

    Exterior dimension (mm)
    Outline dimensions

    Removal height (mm)
    Distance of dis-assembly

    Pipe connection size
    Connecting dimensions
    of pipe

    Pipe installation dimension
    Mounting dimensions of pipe

    DN

     

    H

    B   

    L

    H1

    D

    Do

    C

    h

    L3

    B1

    H2

    15

    C

    328

    180

    196

    260

    M30X2 CB500-75

    38

    55

    88

    155

    291

    20

    C

    310

    207

    260

    230

    M33X2 CB500-75

    34

    65

    90

    177

    258

    25

    D

    315

    323

    230

    270

    M39X2 CB500-75

    34

    65

    90

    185

    265

     

    C

     

    205

    260

     

     

     

     

     

    177

     

    32

    D

    380

    232

    200

    330

    60X 60

    38

    34

    65

    96

    187

    330

     

    C

     

    207

    260

     

     

     

     

     

     

    175

     

    40

    C

    462

    261

    314

    360

    60X60

    45

    43

    70

    110

    224

    363

    Base mounting dimensions
    Mounting dimensions of base

    净重(Kg)Net weight

    h1

    L1

    L2

    b

    R

    n

    d1

     

    45

    166

    80

    12

    16

    4

    12

    9.5

    90

    230

    100

    12

    15

    4

    15

    11.5

    70

    156

     

    12

    15

    2

    16.5

    12

    50

    230

    100

     

     

    4

     

     

    70

    170

     

    12

    15

    2

    16.5

    12

    50

    230

    100

     

     

    4

     

     

    100

    274

    130

    15

    20

    4

    17

    22

    Note: installation form: D-top hanging type C- side type: differential pressure transmitter is optional
    Note:Mount type:D means hang mounting type  C means side mounting type. The differential
    Pressure switch is option.

     

    1

    Main dimension table of SPL dual-cylinder screen-pan oil filter

     


    Nominal diameter (mm)

    Installation form
    Mounting type

    Overall dimension (mm)
    Outline dimensions

    Filter element removal height (mm)
    Distance of dis-assembly

    Pipe connection size (mm)
    Connecting
    dimensions of pipe

    Pipe installation dimension (mm)
    Mounting dimensions of pipe

    DN

     

    H

    B

    L

    H1

    D

    Do

    C

    h

    L3

    B1

    H2

    50

    X

    447

    425

    410

    425

    86X86

    57

    220

    90

    140

    355

    422

    C

    400

    355

    412

    65

    X

    580

    453

    410

    535

    100X100

    70

    365

    105

    160

    375

    527

    C

    423

    370

    517

    80

    X

    780

    541

    492

    660

    116X116

    89

    443

    124

    190

    456

    650

    Base installation dimension (mm)
    Mounting dimensions of base

    净重(Kg)Net Weight

    h1

    L1

    L2

    b

    R

    n

    d1

     

     

    260

    210

    18

    25

    4

    20

    85

    92

    350

    130

     

    260

    210

    20

    25

    4

    20

    120

    112

    350

    150

     

    350

    270

    20

    25

    4

    22

    165

    Note: Installation form: X-is bottom-mounted type and C- is side-mounted type:() The internal dimension is side-mounted type; the differential pressure transmitter is optional.
    Note:Mount type:X means underside mounting type.C means side mounting type.The dimensions in parentheses belong to side mounting type.The differential pressure switch is option.

     

    1

     

    Main dimension table of SPL dual-cylinder screen-pan oil filter

     


    Path
    DN
    (mm)

    Overall dimension (mm)
    Outline dimensions

    Filter element removal height (mm)
    Distance of dis-assembly

    Pipe connection size (mm)
    Connecting dimensions of pipe

    Management installation size (mm)
    Mounting dimensions of pipe

    DN

    H

    B

    L

    H1

    D

    Do

    C

    h

    B1

    L3

    L2

    100

    765

    847

    560

    660

    190

    108

    336

    200

    687

    300

    640

    125

    850

    900

    605

    760

    215

    133

    420

    225

    732

    340

    730

    Base installation dimension (mm)
    Mounting dimensions of base

    Net weight (kg)
    Net Weight

    L1

    L2

    b

    R

    n

    d1

     

    500

    330

    20

    32

    4

    22

    370

    540

    370

    20

    32

    4

    22

    420

    Note: Flange standard GB573; differential pressure transmitter is optional.
    Note:Flange standard:GB573.The differential pressure switch is option

     

    1

     

    Main dimension table of SPL dual-cylinder screen-pan oil filter

     


    Path
    DN
    (mm)

    Overall dimension (mm)
    Outline dimensions

    Filter element removal height (mm)
    Distance of dis-assembly

    Pipe connection size (mm)
    Connecting dimensions of pipe

    Pipe installation dimension (mm)
    Mounting dimensions of pipe

    DN

    H

    B

    L

    H1

    D

    Do

    C

    h

    B1

    L3

    H2

    150

    890

    1000

    990

    790

    240

    159

    380

    250

    825

    400

    760

    200

    1058

    1155

    1180

    945

    310

    219

    450

    315

    960

    440

    910

    Base installation dimension (mm)
    Mounting dimensions of base

    Net weight (kg)
    Net Weight

    L1

    L2

    b

    R

    n

    d1

     

    750

    460

    30

    32

    4

    22

    680

    920

    520

    30

    40

    4

    24

    800

    Note: flange standard GB573; differential pressure transmitter is optional
    Note:Flange standard:GB573; The differential pressure switch is option.

     

    DPL Single-cylinder Mesh Oil Filter for Marine Diesel EngineDPLmarine single-cylinder screen-pan oil filter

     

    1
    Main dimension table of DPL Single-cylinder screen-pan oil filter

     


    Path
    DN
    (mm)

    Overall dimension (mm)
    Outline dimensions

    Filter element removal height (mm)
    Distance of disassembly

    Pipe connection size (mm)
    Connecting dimensions of pipe

    Pipe installation dimension (mm)
    Mounting dimensions of pipe

    DN

    H

    B

    L

    H1

    D

    Do

    C

    h

    B1

    H2

    25

    315

    130

    135

    270

    Pipe joint M39X2

    25

    34

    60

    70

    264

    40

    440

    143

    173

    360

    66X66

    45

    36

    70

    80

    364

    65

    580

    195

    285

    535

    100X100

    70

    79

    105

    105

    517

    80

    700

    238

    320

    685

    ∅ 185

    89

    90

    120

    128

    630

    Base installation dimension (mm)
    Mounting dimensions of base

    Net weight (kg)
    Net Weight

    h1

    L1

    L2

    b

    R

    n

    d1

     

    139

    100

    90

    12

    15

    4

    16

    6

    177

    130

    125

    14

    20

    4

    18

    12

    261

    165

    150

    18

    25

    4

    22

    25

    310

    170

    170

    18

    25

    4

    22

    30

    Note: Flange standard GB573; threaded pipe joint standard CB500; differential pressure transmitter is optional.
    Note:The flange standard is GB573;Screw connection standard CB500; The differential pressure switch is option. 

     

    Main dimension table of DPL single-cylinder screen-pan oil filter

     

    Path
    DN
    (mm)

    Overall dimension (mm)
    Outline dimensions

    Filter element removal height (mm)
    Distance of dis-assembly

    Pipe connection size (mm)
    Connecting dimensions
    of pipe

    Pipe installation dimension (mm)
    Mounting dimensions of pipe

    DN

    H

    B

    L

    H1

    D

    Do

    D’

    Do' handle bar

    C

    h

    I

    C’

    H2

    100

    800

    412

    528

    790

    190

    108

    140

    42

    290

    360

    264

    150

    734

    150

    940

    550

    660

    790

    240

    159

    135

    57

    380

    380

    335

    180

    870

    200

    1050

    612

    750

    945

    310

    219

    135

    57

    438

    400

    368

    180

    980

    Base mounting dimensions
    Mounting dimensions of base

    Net weight (kg)
    Net Weight

    L1

    b

    n

    d1

     

    335

    18

    3

    18

    115

    470

    20

    3

    24

    160

    550

    20

    3

    24

    210

    Note: Flange standard GB573 (can be determined as required); differential pressure transmitter is optional.
    Note:Flange standard:GB573(Also can be determined by consumer);,The differential pressure switch is option.